Physics > Medical Physics
[Submitted on 21 Jan 2025]
Title:Self-Calibrated Epipolar Reconstruction for Assessment of Aneurysms in the Internal Carotid Artery Using In-Silico Biplane Angiograms
View PDFAbstract:The treatment of intracranial aneurysms (IA) relies on angiography guidance using biplane views. However, accurate flow estimation and device sizing for treatment are often compromised by vessel overlap and foreshortening, which can obscure critical details. This study introduces an epipolar reconstruction approach to enhance 3D rendering of the internal carotid artery (ICA) and aneurysm dome using routinely acquired biplane angiographic data. Our method aims to improve procedural guidance by overcoming the limitations of traditional two-dimensional imaging techniques. This study employed three 3D geometries of ICA aneurysms to simulate virtual angiograms. These angiograms were generated using a computational fluid dynamics (CFD) solver, followed by the simulation of biplane angiography using a cone-beam geometry. Self-calibration was accomplished by matching contrast media position as a function of time between biplane views. Feature-matching was used to triangulate and reconstruct vascular structures in 3D. The projection data was utilized to refine the 3D estimation, including elimination of erroneous structures and ellipse-fitting. The accuracy of the reconstructions was evaluated using the Dice-Sorensen coefficient, comparing the 3D reconstructions to the original models. The proposed epipolar reconstruction method generalized well across the three tested aneurysm models, with respective Dice-Sorensen coefficients of 0.745, 0.759, and 0.654. Errors were primarily due to partial vessel overlap. The average reconstruction time for all three volumes was approximately 10 seconds. The proposed epipolar reconstruction method enhanced 3D visualization, addressing challenges such as projection-induced vessel foreshortening. This method provides a solution to the complexity of IA visualization, with the potential to provide more accurate analysis and device sizing for treatment.
Current browse context:
physics.med-ph
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.