Physics > Medical Physics
[Submitted on 7 Jan 2025 (v1), last revised 9 Feb 2025 (this version, v2)]
Title:3D Single-shot CEST imaging at 3T Based on True FISP Readout
View PDFAbstract:To simultaneously fit multiple-pool effects, spectrally selective 3D CEST imaging typically requires single-shot readouts to save time. However, to date, FLASH and EPI have been the primary pulse sequences used for this purpose. They suffer from low SNR or image distortion related to B0 field inhomogeneity. In this work, we developed a 3D single-shot CEST sequence using true fast imaging with steady-state precession (True FISP) readout, also known as bSSFP, and optimized the scanning parameters through simulations. The performance of the CEST sequence was validated using an egg white phantom, ten healthy volunteers, and a patient with a brain tumor on a 3T human scanner. Subsequently, the proposed CEST sequence using True FISP was compared with the commonly used FLASH-based CEST sequence, focusing on SNR and image contrast, while maintaining identical pre-saturation modes, repetition time, echo time and scan time. In the simulation experiments, the maximum CEST signal obtained from the True FISP was significantly greater than that obtained from the FLASH sequence. In the egg white phantom, the SNRs of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) effect images obtained from the True FISP were 68.3% and 57.0% higher than those obtained from the FLASH sequence, respectively. In healthy volunteers, saturated images collected with the True FISP sequence at 3.5 ppm showed an approximate 84% increase in mean temporal SNR compared to those collected with the FLASH sequence. Compared to the FLASH sequence, the CEST images obtained from the True FISP sequence could display more detailed brain tissue structures of both normal individuals and the patient with a brain tumor. Therefore, due to the high SNR inherent in the sequence, True FISP has the potential to be used for fast and high-quality 3D image readout of CEST contrasts in clinical applications.
Submission history
From: Yupeng Wu [view email][v1] Tue, 7 Jan 2025 05:48:08 UTC (1,671 KB)
[v2] Sun, 9 Feb 2025 14:11:08 UTC (1,678 KB)
Current browse context:
physics.med-ph
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.