Physics > Instrumentation and Detectors
[Submitted on 19 Feb 2018 (v1), last revised 16 Mar 2018 (this version, v2)]
Title:Microdosimetry in ion-beam therapy: studying and comparing outcomes from different detectors
View PDFAbstract:Experimental studies of microdosimetry in therapeutic ion beams have been performed using several detectors. The differences among them lie on the shapes, the site sizes, and the material. Coin-shaped solid-state detectors made of silicon or diamond with thickness varying from 0.3 to 10 microns, as well as proportional counters with spherical and cylindrical sensitive volumes filled with tissue-equivalent gas are the microdosimeters used in therapeutic proton and carbon-ion beams. One goal of microdosimetry in the clinical environment is providing repeatable specification of the radiation quality of the radiation field. A methodology should be developed to provide, independently from the heterogeneous information collected with the different detectors, a detector-independent specification of the radiation quality. Historically the specification of the radiation quality is provided either, in terms of Linear Energy Transfer (LET) or in terms of lineal energy, y. First this study focuses on identifying the correlation between the distributions of LET and the lineal energy spectra as well as the correspondence between their mean values calculated in frequency and in dose. The evaluation is based on the method of LET analysis described by Kellerer making the adaptation to the peculiarities of the therapeutic ion-beam where the pristine irradiation is unidirectional and made of a single type of mono-energetic ions. The second objective of this study is to interpret the spectrum collected by a slab and estimate what the spectrum would be if it was collected by a detector different in shape, material, or size. An example confirms the method starting from the simulated lineal energy spectrum obtained for carbon ions in a slab detector of graphite and converting it to the spectruma that would be obtained in the same radiation field for spherical, cylindrical, and slab detector made of water.
Submission history
From: Giulio Magrin [view email][v1] Mon, 19 Feb 2018 17:08:14 UTC (815 KB)
[v2] Fri, 16 Mar 2018 13:55:30 UTC (775 KB)
Current browse context:
physics.ins-det
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.