Physics > Medical Physics
[Submitted on 3 Aug 2023]
Title:Image registration of an electromagnetic tracking enabled afterloader and CT using a phantom for the quality control of implant reconstruction
View PDFAbstract:Electromagnetic tracking (EMT) shows great potential for automating implant reconstruction in brachytherapy. One of the challenges of this technology is that it does not intrinsically share the same reference frame as the patient's medical imaging. The purpose of this work is to register the reference frames of an EMT-enabled afterloader and a CT scan image of a rigid phantom for quality control of EMT-based implant reconstruction. The geometry of twelve 6F catheters and a tandem and ring gynecological applicator were reconstructed using an EMT sensor attached to an afterloader's check cable. All EMT reconstructions were done in three different environments: disturbance free, CT-on-rails brachytherapy suite and MRI brachytherapy suite. Implants were reconstructed using two acquisition methods: step-and-record and continuous motion. A CT scan of the phantom was obtained and manually reconstructed in the treatment planning system, with the help of the solid model of the applicator. Rigid registration algorithms were used to register EMT and CT scan reference frames using corresponding points from the EMT and CT based reconstructions of the phantom, following three approaches: one gynecological applicator, four catheters inside four calibration plates having and S-shaped path, and four ceramic marbles within the calibration plates. The absolute median deviation from the expected value for EMT measurements in all three environments significantly lie below the sensor's expected accuracy of 0.70 mm (p < 0.001), suggesting that the environment did not have a significant impact on the measurements, given that care is taken in the immediate surroundings. In all three environments, the two acquisition and three registration approaches have a mean and median registration errors (perpendicular distance) that lie at or below 1 mm, which is lower than the clinical acceptable threshold of 2 mm.
Submission history
From: Isaac Neri Gomez-Sarmiento [view email][v1] Thu, 3 Aug 2023 19:58:11 UTC (1,532 KB)
Current browse context:
physics.med-ph
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
Connected Papers (What is Connected Papers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.