Physics > Instrumentation and Detectors
[Submitted on 13 Jun 2023 (v1), last revised 11 Oct 2023 (this version, v3)]
Title:Noise and Thermal Performance of a Sub-Attofarad Capacitance Sensor for Precision Measurements, with Applications in Gravitational Wave Detectors
View PDFAbstract:We describe the design principles, fabrication, and characterization of a precision AC resonant capacitance bridge (RCB) sensor, based on a resonant differential planar printed circuit board transformer with a solid (ungapped) MnZn ferrite core, demonstrating a short-term sensitivity at 293 K of 0.225 +/- 0.005 aF/rtHz, at around 120 kHz resonance frequency and 1 Hz Fourier measurement frequency. At 120 K the RCB short term noise sensitivity is 0.118 +/- 0.005 aF/rtHz. We compare the ungapped configuration to five different RCBs; three with a core gap of 65 um and two with a core gap of 130 um. Their average room temperature short term noise sensitivities are 0.30 +/- 0.01 aF/rtHz and 0.45 +/- 0.01 aF/rtHz, while the cryogenic operation of these transformers at 120 K resulted in averaged sensitivities of 0.23 +/- 0.01 aF/rtHz and of 0.36 +/- 0.01 aF/rtHz respectively. Multi-hour room temperature runs, with one core of each of the three gap types, proved the stability of their long-term sensitivities of 0.234 +/- 0.005 aF/rtHz, 0.338 +/- 0.009 aF/rtHz, and 0.435 +/- 0.010 aF/rtHz for the ungapped (40-hour duration) and the 65 um and 130 um (28-hour duration) cores respectively. At 0.1 mHz, a critical frequency for space gravitational wave detectors, the respective sensitivities are 0.25 +/- 0.02 aF/rtHz, 0.35 +/- 0.02 aF/rtHz, and 0.53 +/- 0.07 aF/rtHz. Measurements with the ungapped transformer configuration for temperatures from 325 K to 349 K further validate the dependence of the noise model on the temperature and permeability. The performance of our RCB with an ungapped core matches the calculated performance value and shows an improvement in signal-to-noise of two or more compared with capacitance bridges developed for similar applications. A further factor of about two noise reduction is achieved by cooling to 120 K.
Submission history
From: Shally Saraf [view email][v1] Tue, 13 Jun 2023 20:36:03 UTC (1,014 KB)
[v2] Fri, 16 Jun 2023 01:50:45 UTC (1,014 KB)
[v3] Wed, 11 Oct 2023 22:07:38 UTC (1,730 KB)
Current browse context:
physics.ins-det
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.