Astrophysics > Instrumentation and Methods for Astrophysics
[Submitted on 9 Nov 2022 (this version), latest version 18 Nov 2022 (v2)]
Title:StarDICE I: sensor calibration bench and absolute photometric calibration of a Sony IMX411 sensor
View PDFAbstract:The Hubble diagram of type-Ia supernovae (SNe-Ia) provides cosmological constraints on the nature of dark energy with an accuracy limited by the flux calibration of currently available spectrophotometric standards. The StarDICE experiment aims at establishing a 5-stage metrology chain from NIST photodiodes to stars, with a targeted accuracy of \SI{1}{mmag} in $griz$ colors. We present the first two stages, resulting in the calibration transfer from NIST photodiodes to a demonstration \SI{150}{Mpixel} CMOS sensor (Sony IMX411ALR as implemented in the QHY411M camera by QHYCCD). As a side-product, we provide full characterization of this camera. A fully automated spectrophotometric bench is built to perform the calibration transfer. The sensor readout electronics is studied using thousands of flat-field images from which we derive stability, high resolution photon transfer curves and estimates of the individual pixel gain. The sensor quantum efficiency is then measured relative to a NIST-calibrated photodiode. Flat-field scans at 16 different wavelengths are used to build maps of the sensor response. We demonstrate statistical uncertainty on quantum efficiency below \SI{0.001}{e^-/\gamma} between \SI{387}{nm} and \SI{950}{nm}. Systematic uncertainties in the bench optics are controlled at the level of \SI{1e-3}{e^-/\gamma}. Uncertainty in the overall normalization of the QE curve is 1\%. Regarding the camera we demonstrate stability in steady state conditions at the level of \SI{32.5}{ppm}. Homogeneity in the response is below \SI{1}{\percent} RMS across the entire sensor area. Quantum efficiency stays above \SI{50}{\percent} in most of the visible range, peaking well above \SI{80}{\percent} between \SI{440}{nm} and \SI{570}{nm}. Differential non-linearities at the level of \SI{1}{\percent} are detected. A simple 2-parameter model is proposed to mitigate the effect.
Submission history
From: Marc Betoule M. [view email][v1] Wed, 9 Nov 2022 14:33:27 UTC (4,117 KB)
[v2] Fri, 18 Nov 2022 11:22:38 UTC (4,117 KB)
Current browse context:
astro-ph.IM
Change to browse by:
References & Citations
Bibliographic and Citation Tools
Bibliographic Explorer (What is the Explorer?)
Connected Papers (What is Connected Papers?)
Litmaps (What is Litmaps?)
scite Smart Citations (What are Smart Citations?)
Code, Data and Media Associated with this Article
alphaXiv (What is alphaXiv?)
CatalyzeX Code Finder for Papers (What is CatalyzeX?)
DagsHub (What is DagsHub?)
Gotit.pub (What is GotitPub?)
Hugging Face (What is Huggingface?)
Papers with Code (What is Papers with Code?)
ScienceCast (What is ScienceCast?)
Demos
Recommenders and Search Tools
Influence Flower (What are Influence Flowers?)
CORE Recommender (What is CORE?)
IArxiv Recommender
(What is IArxiv?)
arXivLabs: experimental projects with community collaborators
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.